ICS-40730 un-usable

By remis , 26 June 2019

Hello.
You can see on the picture the two output of ICS. Supply is a battery (3V) with shorts wires connected to ground and VCC directly on package with 470nF decoupling capacitor. Connections to oscilloscope probe touching the pads : 1 Mohms, without any wire. Datasheet explain this Mic can be used in single ended mode. It is not possible with this spurious at 26 Khz. I confirm the result on many parts same ref. Could you confirm?
Regards.

remis

6 years 8 months ago

I confirm the same issue on ICS40720

phpbb Post ID
37568

jijiang

6 years 3 months ago

Looks like you have tons of noise coupled into the measurement. Please note microphone output is very weak, and noise from many places can easily be coupled in.