We are using the MPU6050 chips on our custom PCBs.
We are facing some issues while testing MPU6050 chip and wanted too reach out to see if there were any known solutions/directions. 30% of the PCB's are showing 0(zero) values upon initialization, and we know initilaization is not an issue because other pcbs are working as expected. 30% of other pcbs are showing major offsets. Is there any way to calibrate 6050 chips on our pcbs? Please see attached images for reference.
Is there anyone who have reported the same issue.
Hi, I want to point out that MPU6050 is an End-of-Life product. You can check out our newer products here: https://invensense.tdk.com/products/motion-tracking/6-axis/
Thank you for the response.
we are having high percentage of rejection due to MPU-6050 failure/malfunction ,in this regard please suggest to us any specific precautions to be taken during the assembly which may help to reduce rejection.
Hi,
Take a look at this document https://invensense.tdk.com/download-pdf/an-000393-imu-pcb-design-and-mems-assembly-guidelines/